ARMEN INSTRUMENT HPLC PUMPS

PRODUCT
REFERENCE
GENERAL SPECIFICATIONS 
COMMENTS
AP - 100  family
 
 
 
TWO HEAD PUMP
AP - 100 - 250 - 2
Flow rate :0,2 to 100 ml/mn - 250 bar
Isocratic - Pulseless flow & pulsated suction flow
THREE HEADS PUMP
TRANSFORMATION 2 INTO 3 HEADS
AP - 100 - 250 - 3
AP - 100 / 2 to 100 / 3
Flow rate : 0,2 to 100 ml/mn - 250 bar
Isocratic - Pulseless flow & Pulseless suction flow (To connect to the suitable gradient  module)
GRADIENT FORMER  100
 
 
 
2 ELUENTS
GF 100 - 2
Linear response from 0,5 to 99,5%
The Gradient Former must be used with 3 heads pump for the best accuracy.
3 ELUENTS
GF 100 - 3
Linear response from 0,5 to 99,5%
The Gradient Former must be used with 3 heads pump for the best accuracy.
4 ELUENTS
GF 100 - 4
Linear response from 0,5 to 99,5%
The Gradient Former must be used with 3 heads pump for the best accuracy.
INJ THROUGH PUMP
INJ 100
Manual or volumetric injection by 1 ml steps
Instaled on the Gradient Former (Added INJ 100 at the ref of the Gradient Former)
INJECTIONTHROUGH PUMP UNIT
INJ - S - 100
Manual or volumetric injection by 1 ml steps
To inject through the Pump when the Pump is not equipted with the Gradient Former
FRACTION COLLECTOR
FC 100
 
One waste plus 7 collects - Is oparated from the Pump.
OPTION FOR BIOCOMPATIBLE PUMP AP150 -2 (2 HEADS)
OPTION FOR BIOCOMPATIBLE PUMP AP150 -3 (3 HEADS)
PRODUCT
REFERENCE
GENERAL SPECIFICATIONS 
COMMENTS
AP - 250 - 500 family
 
 
 
TWO HEAD PUMP
AP - 250 - 200 - 2
Flow rate : 0,5 to 250 ml/mn - 200 bar
Isocratic - Pulseless flow & pulsated suction flow
THREE HEADS PUMP
AP - 250 - 200 - 3
Flow rate : 0,5 to 250 ml/mn - 200 bar
Isocratic - Pulseless flow & Pulseless suction flow
TWO HEAD PUMP
AP - 500 - 100 - 2
Flow rate : 1 to 500 ml/mn - 100 bar
Isocratic - Pulseless flow & pulsated suction flow
THREE HEADS PUMP
AP - 500 - 100 - 3
Flow rate : 1 to 500 ml/mn - 100 bar
Isocratic - Pulseless flow & Pulseless suction flow
TWO HEAD PUMP
AP - 500 - 200 - 2
Flow rate : 1 to 500 ml/mn - 250 bar
Isocratic - Pulseless flow & pulsated suction flow
THREE HEADS PUMP
AP - 500 - 200 - 3
Flow rate : 1 to 500 ml/mn - 250 bar
Isocratic - Pulseless flow & Pulseless suction flow
OPTION FOR BIOCOMPATIBLE PUMP AP250 & 500 -2 (2 HEADS)
OPTION FOR BIOCOMPATIBLE PUMP AP250 & 500 -2 (2 HEADS)
OPTIONS FOR 250 / 500ml/min maximum flow rate Pump
GRADIENT FORMER 250/500
2 ELUENTS
GF 250/500 - 2
Linear response from 0,5 to 99,5%
The Gradient Former must be used with 3 heads pump for the best accuracy.
3 ELUENTS
GF 250/500 - 3
Linear response from 0,5 to 99,5%
The Gradient Former must be used with 3 heads pump for the best accuracy.
4 ELUENTS
GF 250/500 - 4
Linear response from 0,5 to 99,5%
The Gradient Former must be used with 3 heads pump for the best accuracy.
INJ THROUGH PUMP
INJ 250/500
Manual or volumetric injection by 1 ml steps
Instaled on the Gradient Former (Added INJ 250/500 at the ref of the Gradient Former)
INJECTIONTHROUGH PUMP UNIT
INJ - S - 250 - 500
Manual or volumetric injection by 1 ml steps
To inject through the Pump when the Pump is not equipted with the Gradient Former
FRACTION COLLECTOR
FC 250 - 500
 
One waste plus 7 collects - Is oparated from the Pump.
HEADS & ACCESSORIES BATCH TO MODIFY THE MAXIMUM FLOW RATE :
250 ml/min
BT250 - 2
 
 
250 ml/min
BT250 - 3
 
 
500 ml/min
BT500 - 2
 
 
500 ml/min
BT500 - 3
 
 
PRODUCT
REFERENCE
GENERAL SPECs
COMMENTS
AP - 1000 - 2000 - 4000  family
 
 
TWO HEAD PUMP
AP - 1.000 -150 - 2
Flow rate : 2 to 1.000 ml/mn - 150 bar
Isocratic - Pulseless flow & pulsated suction flow
THREE HEADS PUMP
AP - 1.000 -150 - 3
Flow rate : 2 to 1.000 ml/mn - 150 bar
Isocratic - Pulseless flow & Pulseless suction flow
TWO HEAD PUMP
AP - 2.000 -75 - 2
Flow rate : 4 to 2.000 ml/mn - 75 bar
Isocratic - Pulseless flow & pulsated suction flow
THREE HEADS PUMP
AP - 2.000 -75 - 3
 
Isocratic - Pulseless flow & Pulseless suction flow
TWO HEAD PUMP
AP - 4.000 -050 - 2
Flow rate : 8 to 4.000 ml/mn - 50 bar
Isocratic - Pulseless flow & pulsated suction flow
THREE HEADS PUMP
AP - 4.000 -050 - 3
Flow rate : 8 to 4.000 ml/mn - 50 bar
Isocratic - Pulseless flow & Pulseless suction flow
OPTION FOR BIOCOMPATIBLE PUMP AP1000, 2000 & 4000 -2 (2 HEADS)
OPTION FOR BIOCOMPATIBLE PUMP AP1000, 2000 & 4000 -3 (3 HEADS)
OPTIONS FOR 1.000 and 2.000ml/min maximum flow rate Pump
GRADIENT FORMER 1000/2000
 
 
2 ELUENTS
GF 1.000/2.000 - 2
Linear response from 0,5 to 99,5%
The Gradient Former must be used with 3 heads pump for the best accuracy.
3 ELUENTS
GF 1.000/2.000 - 3
Linear response from 0,5 to 99,5%
The Gradient Former must be used with 3 heads pump for the best accuracy.
4 ELUENTS
GF 1.000/2.000 - 4
Linear response from 0,5 to 99,5%
The Gradient Former must be used with 3 heads pump for the best accuracy.
INJ THROUGH PUMP
INJ 1000/2000/4000
Manual or volumetric injection by 1 ml steps
Instaled on the Gradient Former (Added INJ 250/500 at the ref of the Gradient Former)
INJECTIONTHROUGH PUMP UNIT
INJ 1000/2000/4000
Manual or volumetric injection by 1 ml steps
To inject through the Pump when the Pump is not equipted with the Gradient Former
FRACTION COLLECTOR
FC 1.000/2.000
 
One waste plus 7 collects - Is oparated from the Pump.
HEADS & ACCESSORIES BATCH TO MODIFY THE MAXIMUM FLOW RATE :
1000 ml/min
1000 ml/min
2000 ml/min
2000 ml/min
4000 ml/min
4000 ml/min
BT1000 - 2
BT1000 - 3
BT2000 - 2
BT2000 - 3
BT4000 - 2
BT4000 - 3
 
 
GENERAL OPTIONS & ACCESSORIES
QUANTITY
 
THE MEMBRANE PUMP IS DELIVERED WITH :
CLP50
1 - 4
Developed to pump liquid through the "cleaning-discs" of Armen HPLC Preparative Pumps.
One 1litre glass bottle.
Flow rate 20 to 80ml/min
5 - 9
Can be used for other applications, such as the transfer of neutral or corrosive liquids.
2 µm stainless steel frit for the suction tube.
 
10 - 14
 
Four meters of 1/8" PTFE tubing.
 
15 et +
 
Fittings
 
 
 
COOLED HEADS
UC+MODULE REF
Circuits for cooled liquid inside the heads
To special order - The refrigerant system is not supplied with the pump
EXPLOSION-PROOF
EP+MODULE REF
 
To special order.
PNEUMATIC INTERFACE (in the Inj module)
PI9901
 
 
PNEUMATIC INTERFACE (in a special cabinet)
PI9902
 
 
BORWIN DATA ACQUISITION SYSTEM FOR ARMEN PUMP FAMILY
BORWIN 1 - SOFT
 
INTERFACE DATA ACQUISITION HERCULE 2,000
FLASH PUMP
 
 
 
Isochratic Binary Ternary Quaternary
 
 
 
Flow rate
0,2 to 100ml/min
 
 
Max pressure
25bar
 
 
TERM OF PAYMENT :   
1/3 with order, the balance 30 days net after delivery
GUARANTEE :     
2 Years or 9,000 hours
Excepted for consumable parts, as seals, pistons check valves.
 
1 Year
For Gradient former, Fraction collector, Through pump Injection valve & BORWIN
DELIVERY TIME :   
2 months maximum
 
SUPPLIER CONDITIONS :   
Chromalytic ensures the GUARANTY and services (We supply the spare parts free of charge during the GUARANTY
We train your end-users iin the PUMP operation
ARMEN INSTRUMENTS warrants that the items delivered are free from defects in workmanship and material.

08

NEW Website

Chromalytic Technology - Australian Distributors 'specialising in chromatography'
:  GC, HPLC & Fluid Transfer Products; Instrumentation  Home : Sections

07

the Web Ask chromtech.com.au