Pinnacle II HPLC Columns | 2002 / 2003 |
Pinnacle columns are manufactured using Restek silica, which features a controlled particle size distribution and spherical shape. With the design of Pinnacle II columns, Restek achieves complete control over the HPLC column manufacturing chain. We can go a step further than most to ensure consistent quality and reproducibility because we manufacture the silica, perform the stationary phase bonding and column packing in-house, and apply our stringent quality testing throughout the whole process. The ability to consistently manufacture silica at a specified pore volume, surface area, pore size distribution, and particle size is part of the equation in providing columns that achieve reproducible analyses. Pharmaceutical ApplicationsNotice how a Pinnacle II C18 column provides good peak shape for acetaminophen and codeine phosphate. Nutraceutical and Food ApplicationsThe Institute for Nutraceutical Advancement (INA) has published a series of methods for the determination of active compounds in nutraceutical products. As society's taste in spicy foods grows, so does the need to test and classify products and raw materials for their heat levels. AOAC Method 995.03 specifies the separation of the three target capsaicinoids responsible for the heat in chili peppers. Using a gradient elution program, an efficient separation of these compounds is achieved with the Pinnacle IIâ„¢ C18 column. Environmental ApplicationsPinnacle II HPLC
columns provide a cost-effective tool for many traditional methods used in the environmental industry, including US Environmental Protection Agency (EPA) Restek controls Pinnacle II raw material quality from the very beginning of the silica manufacturing process. Add our phase bonding and column packing experience to this high level of quality control, and you benefit from even better column-to-column and analysis-to-analysis reproducibility. | Many New Phases Additional stationary phases will be joining this family of products. Keep watching our web site for additional stationary phases as they are introduced. |
Base-Deactivated Columns Coming Soon ! | |
Hot Tech Tip High backpressure is one of the most common problems encountered when performing HPLC analysis. Normal column backpressure is observed after a new column has been installed and equilibrated with the mobile phase. Unfortunately, this pressure will often increase with use because of particles collecting on the column inlet frit. These particles can be sample impurities, mobile phase contaminants, or materials from the injector or autosampler rotor seal. The presence of particles can result in increased backpressure, split peaks, tailing, and eventually over-pressure shut-down. In some circumstances, these problems can be corrected by back-flushing the column. However, in many cases the result is an unusable column. To reduce backpressure problems, all samples and mobile phase solvents must be filtered before use, and rotor seals should be changed on a routine basis. Along with these preventative measures, it is advisable to use column prefilters such as the Trident Direct column protection system. Particles build up on the inexpensive, replaceable frit in the prefilter, instead of the permanent frit at the head of the column. | |
TRIDENT Guard Columns Restek offers the Trident Direct guard cartridge system. All of our Pinnacle II phases are available in guard columns. The Trident Direct system features three levels of protection against many of the contaminated samples that analysts inject into a system. Restek also offers a full line of HPLC accessories -- everything from PEEK fittings to syringes. For more information on the Trident Direct guard column system and a complete product offering, see elsewhere |
Pinnacle II C8 5µm Columns
Length | 1.0mm ID | 2.1mm ID | 3.2mm ID | 4.6mm ID |
C8 |
50mm | 9213551 | 9213552 | 9213553 | 9213555 |
Length | 1.0mm ID | 2.1mm ID | 3.2mm ID | 4.6mm ID | C18 |
50mm | 9214551 | 9214552 | 9214553 | 9214555 |
Length | 1.0mm ID | 2.1mm ID | 3.2mm ID | 4.6mm ID | Phenyl |
50mm | 9215551 | 9215552 | 9215553 | 9215555 |
Length | 1.0mm ID | 2.1mm ID | 3.2mm ID | 4.6mm ID | Cyano |
50mm | 9216551 | 9216552 | 9216553 | 9216555 |
Pinnacle II | |
by Greg France, HPLC Product Marketing Manager |