|
|
![]() |
| |
|
Dynacalibrators®
VICI Metronics Dynacalibrators® allow you to verify the accuracy of analytical data from air
pollution monitoring, industrial hygiene surveys, odor surveys, and other instruments measuring gas
concentration. All models enable calibrations traceable to NIST standards for almost any gas
analyzer, in the lab or in the field.The design takes full advantage of all the conveniences inherent in our Dynacal® permeation devices to generate and deliver precise concentrations ranging from ppb to high ppm for hundreds of different compounds. Standard features on all our models, from the most basic Model 190 to the most fully-equipped Model 500, facilitate accurate, reproducible, trouble-free calibrations time after time.
Model 190The Model 190 is our basic model, offering all the standard features and configurations - solid state proportional temperature controller, digital readout for set point and chamber temperature, stainless steel inlet and outlet, pyrex chamber, and cooling fan. Options include a high pressure chamber for operation at 50 psi, an overflow outlet with activated charcoal scrubber, and variable or fixed flow control. Product brochure (PDF format)
Model 230With a flexible flow metering system to maintain a constant carrier flow through the permeation chamber, the Model 230 allows the dilution flow to be varied over a wide range, generating the spectrum of concentrations required for checking analyzer linearity. Like all Dynacalibrators, its large permeation chamber is big enough to accomodate several permeation devices, for higher output concentrations or multi-component mixtures. Product brochure (PDF format) Model 340 The Model 340 adds a front panel mode control switch to select among zero, span, or remote calibration modes. In the zero mode, scrubbed air is delivered to the stream outlet. In the remote mode, the Model 340 can be externally programmed to deliver a zero and a span reference on command. Product brochure (PDF format)
Model 450Ordinarily, plumbing connections between the sample manifold, the analyzer, and the calibrator must be changed for each calibration. The Model 450’s unique "through-port" feature eliminates this chore. The mode control switch selects among standby, zero, span 1 (low concentration), span 2 (high concentration), and remote modes. In the remote mode, the Model 450 can be externally programmed to operate in all of its functional modes. Product brochure (PDF format) Model 500 This innovative design features two separate permeation chambers with independent temperature control systems. The chambers can be used independently, or together to combine concentrations of trace components. Separate solenoid valves allow the carrier flows to be switched from the dilution flow to a vent port. Portable dynacalibrator® Completely portable Pump powered by rechargeable battery Available temperature control from 20°C to 100°C Utilizes permeation devices - no bulky cylinders
Standard features on Models 115 and 120 include a glass permeation chamber with screw cap access,
digital readout for chamber temperature, a flowmeter and flow control valve, span and overflow
outlets, a 12 VDC internal pump, an activated charcoal scrubber, and a molded fiberglass case. The
Model 120 includes a solid state proportional temperature controller, with digital readout for the
set point and chamber temperature and a heater switch with LED indicator.Spec sheet (PDF format)
|
||||||||||||||||||||||||||||||||||||||
|
Home | PRODUCTS | Search | Catalog | Contact VICI Prices in USD > Aud Plus Import Freight + 10% GST |
||||||||||||||||||||||||||||||||||||||||
| © 2001 VICI VICI ® is a registered trademark of Valco Instruments Co. Inc. and VICI AG |
||||||||||||||||||||||||||||||||||||||||