Chromatography Hints | |||||
Restek ADVANTAGE Articles | |||||
GC Operating Hints *.pdf | Main Features | Advantage Issue (links | |||
Windows Version of EzGC and ProEzGC at reduced price
| - Restek '98 Cat - 392-393) | ||||
Septum Nut Torque, Septum Nut Design, Manual Injection vs Autosampler | December 93 p10-11 | ||||
- Konrad Grob | Summer 97 | ||||
Sample Evaporisation in Hot Injectors | - Konrad Grob |
| |||
Vaporising Split Injectors | Evaporation, Syringe Needle Temperature, Vaporisation/Recondensation Affects on Split Ratio |
| |||
Are GC Techniques really optimised - Splitless Injection as an example | - Konrad Grob | Summer 96 | |||
Different types Split with wool, cup splitter, laminar cup splitter, cyclosplitter. Splitless - straight tube, gooseneck. Operating Hints. Packed Inlets for Dirty samples | July 1991 p6-8 | ||||
- Konrad Grob | Spring 97 | ||||
For an inert sample pathway, Glass wool or beads ?, Redeactivation ? | September 93 p12-13 | ||||
Reduced Breakdown & Adsorption of Sensitive Compounds; Reduced Discrimination and Flash-back | May 1992 p12-13 | ||||
Why Uncoated Guard Columns Allow Injection of Large Sample Volumes | - Konrad Grob |
| |||
Less column maintenance, Improves resolution,, protects column,. Connection, replacement ? How long ? | July 93 p8-9 | ||||
Highly Inert Alternative to Glass Wool |
| ||||
Y-Press-tights, Two-hole ferrules, Direct Injection Tees | April '94 | ||||
Dual Column analysis increases the qualitative and quantitative accuracy; . . . with On-column & direct injection; choosing a confirmational column | July 1992 p10-11 | ||||
Carrier Gases for GC | - Konrad Grob | Fall 97 | |||
- Konrad Grob |
| ||||
- Konrad Grob | Int Supp `96 | ||||
- Konrad Grob | Spring 97 | ||||
What is column overload. How does solubility, film thickness retention, column ID affect column capacity | December 94 p12-13 | ||||
|
| ||||
Bleed - causes, accurate measurement, minimising bleed | January 1992 p8-9 | ||||
Optimising Linear Velocity and Temperature Program Capillary Chiral Analysis | - Konrad Grob | Winter 98 Int'l | |||
The Most Powerful GC Optimisation Software with New Features | Summer 97 | ||||
| Winter 98 | ||||
Into a Vaporising Injector, Needle Length in Manual Splitless, Techniques for Cold )n-column Injection | Volume 6, No 1 p12-13 | ||||
100u column DO pose some practical problems in injection speed and detector sensitivity - discussion of time saving for standard columns | Winter 98 | ||||
Operation, Detector Gases, maintenance, Operating Hints | October '94 p12-13 | ||||
|
| ||||
Operation of . . , Hints, Mauntenance, Troudleshooting | June '94 p6-7 | ||||
Internal Standards,, surrogate standards | September 92 p3-4 | ||||
|
| ||||
| November 1991 p6-7 | ||||
| |||||