G-CAL Gas Calibrators NEW 2003 | Metronics : GC Industries |
for Toxic Gas analysers, process control GCs and lab use - Chemical, petrochem, paper , power plants
- Intrinsically safe design - Class 1, Division 1 applications
- for BOTH gases and "volatile" liquids ( 100 different types )
- ppB to ppM concentrations
-
patented technology - dual polymeric film
- reduced temperature dependency
- less need for a temperature controlled oven
- Calibration chart supplied
- 12 months guaranteed operating life
for Highest accuracy - oven required
Basic Modes - with different configurations Model GC2300 Series - single tube oven portable with in-built pump for field or lab use. detailed specs | 
|
Enquire re availability of multi-tube oven devices previously available from GC Industries / Metronics Model GC2550 Model GC9300 - on-line system use; for 10 internal G-Cal tubes, NEMA-4 SS housing Model GC9500 - as above - 6 G-Cal |

|
G-Cal Permeation Tubes | 
|
G. C. Industries'
Patented G-CAL Permeation Device offers a proven and repeatable means of generating a desired gas or vapor in nanograms/minute (ng/min) range. This gas is then mixed with a carrier gas (O2 and Nitrogen are the most common) at a controlled flow rate to obtain a known mixture in ppm or ppb. Applications of the G-CAL Devices may include calibration of gas monitoring systems and chromatographs, accuracy check of gas detectors, and generation of known compounds into a custom application. |
- Lowest Temperature Sensitivity:
G-CAL units' polymer permeation rate changes range from 1% to 3% per degree C. Teflon rates can change up to 15% per degree C.
- Wide Operating Range & Materials:
- A G-CAL device may be used to generate
concentrations from less than 10 nanograms/minute to 50,000 ng/min and over. G-CAL devices for over 100 different substances are available. The list includes some substances which are in gas phase at ambient temperature, such as CO. Click the link at the top of the page for a partial listing of available chemical compounds.
- Enhanced User Safety:
Two separate polymer permeation barriers plus leak-proof
sintered stainless steel disc construction are tested to withstand pressures of 300% greater than encountered in the field or laboratory. Individual Certification: Each G-CAL device is individually calibrated and vertified to generate a given output (ng/min) vs. temperature in degree Celsius. A graph is included with each device which shows permeation rate vs. temperature from 0 to 50ºC. D.O.T. Shipping Exemption: DOT-E 9969 - Rev. 1, based on the inherently safe design of
G-CAL Permeation Devices, permits their shipment quickly by overnight air or economically by small package surface the same way as any non-hazardous materials
|