G-CAL Gas Calibrators NEW 2003

Metronics : GC Industries

for Toxic Gas analysers, process control GCs
and lab use

  • Chemical, petrochem, paper , power plants
  • Intrinsically safe design - Class 1, Division 1 applications
  • for BOTH gases and "volatile" liquids ( 100 different types )
  • ppB to ppM concentrations
  • patented technology - dual polymeric film
  • reduced temperature dependency
    - less need for a temperature controlled oven
  • Calibration chart supplied
  • 12 months guaranteed operating life
    for Highest accuracy - oven required

Basic Modes - with different configurations
Model GC2300 Series - single tube oven portable with in-built pump for field or lab use. detailed specs

Enquire re availability of multi-tube oven devices
previously available from GC Industries / Metronics
Model GC2550
Model GC9300
- on-line system use; for 10 internal G-Cal tubes, NEMA-4 SS housing
Model GC9500 - as above - 6 G-Cal

G-Cal Permeation Tubes

G. C. Industries' Patented G-CAL Permeation Device offers a proven and repeatable means of generating a desired gas or vapor in nanograms/minute (ng/min) range. This gas is then mixed with a carrier gas (O2 and Nitrogen are the most common) at a controlled flow rate to obtain a known mixture in ppm or ppb.
Applications of the G-CAL Devices may include calibration of gas monitoring systems and chromatographs, accuracy check of gas detectors, and generation of known compounds into a custom application.
  • Lowest Temperature Sensitivity:
    G-CAL units' polymer permeation rate changes range from 1% to 3% per degree C. Teflon rates can change up to 15% per degree C.
  • Wide Operating Range & Materials:
  • A G-CAL device may be used to generate concentrations from less than 10 nanograms/minute to 50,000 ng/min and over. G-CAL devices for over 100 different substances are available. The list includes some substances which are in gas phase at ambient temperature, such as CO. Click the link at the top of the page for a partial listing of available chemical compounds.
  • Enhanced User Safety:
    Two separate polymer permeation barriers plus leak-proof sintered stainless steel disc construction are tested to withstand pressures of 300% greater than encountered in the field or laboratory.
    Individual Certification:
    Each G-CAL device is individually calibrated and vertified to generate a given output (ng/min) vs. temperature in degree Celsius. A graph is included with each device which shows permeation rate vs. temperature from 0 to 50ºC.
    D.O.T. Shipping Exemption:
    DOT-E 9969 - Rev. 1, based on the inherently safe design of G-CAL Permeation Devices, permits their shipment quickly by overnight air or economically by small package surface the same way as any non-hazardous materials

G-Calibrators

Portable G-Calibrator Specs GC2300 Series
Stationary Gas Calibrator
GC9300&9500

  • G. C. Industries' Gas Calibrators (G-Calibrators™) are rugged & portable units specifically designed for use with the company's patented Series 23 G-CAL permeation devices. G-Calibrators generate known concentrations of various gases and liquid vapors, in the ppb to ppm range. This combination offers the easiest method of calibrating toxic gas detection equipment, gas analyzers, and chromatographs. These calibrators are commonly used in the chemical, petrochemical, paper, power plants and related industries.
  • Due to its patented permeation technology, the permeation rate of a G-CAL device remains fairly stable when exposed to changing temperatures. For most applications, this feature eliminates the need for a temperature-controlled oven which is necessary in calibrators that use Teflon permeation tubes. Each G-CAL permeation device is individually calibrated and certified. A permeation curve between -10ºC and 50ºC is also provided with each G-CAL device. Most G-CAL devices are guaranteed for 12 months operating life.

    Portable Gas Calibrator
    Available Features

 GC2300 GC2300 Series Calibrators

  • For field and laboratory
  • Designed to be intrinsically safe
    - Class 1, Division 1 application
  • Powered by a 12V rechargeable nicad battery - charger provided
  • Ambient temperature from -15°C to 45°C
  • Built-in pump
  • Carrier gas flow rates from 100-1000 cc/mt
  • Heater for Internal G-Cal Permeation Device enable constant temperature control for stability at cold temperatures field sites.

 

Stationary Gas Calibrators
( multi-tube oven * )
Check with us for the availability of the following devices from other sources
* No longer available from Metronics

GC9300

  • For on-line system use
  • Heater block accepts 10 internal G-CAL units, maximum
  • Available with dual digital temperature controllers with RTD sensors accurate to ±0.2°C
  • NEMA-4 stainless steel housing

 GC9500

  • For on-line system use
  • Heater block accepts 6 internal G-CAL units, maximum
  • Available with dual digital temperature controllers with RTD sensors accurate to ±0.2°C
    • NEMA-4 stainless steel housing

08