the Web Ask chromtech.COM.au
 

 

 

 

NEW Website 08 here

 

 

 

 

 

 

 

Simple HOMEHome Section Home>Frames  Section-Home

~Prices/CatNo

 

 GC Detectors - DET Thermionic Detectors (TID)

direct from the Inventor of TSD and TID

DET Products -  2006 Aust Prices PDF 10p 3mb acrobat-but12

 

 

DET_NPD-TID02

Det-CurrentSupply02

det46-4

multiple modes of detection (NPD, PTID, TID-1, TID-3, TID-5, FTID, FID, Remote FID, Tandem TID)
unique selective responses to hetero-atom compounds
( Nitrogen, Phosphorus, Oxygenates, Halogenates, Nitro-compounds, Lead, Tin, Silicon )

inexpensive, easy to operate equipment (most modes do not require high purity detector gases)
DETECTORS for GAS CHROMATOGRAPHY - hardware designed to custom fit onto the existing FID or NPD base on various GC models (e.g., Agilent 6890, HP 5890, Varian 3800, SRI 8610)

CERAMIC ION SOURCES (Beads) FOR THE NPD (Nitrogen-Phosphorus Detector)
AND OTHER TID (Thermionic Ionization Detector) MODES,
INCLUDING REPLACEMENTS FOR THE AGILENT 6890 NP ION SOURCE

STAND-ALONE TRANSDUCERS and DETECTION MODULES

Examples of some applications:

  • drugs of abuse with NPD (TID-4).
  • pesticides and environmental pollutants with NPD (TID-2 or TID-4).
  • nitro explosives with TID-1 and NPD (TID-4).
  • phenols and carboxylic acids in foods and flavors analyses with TID-1.
  • oxygenates and N-compounds in petroleum samples with TID-1 and NPD.
  • Pb or Sn in complex matrices with REMOTE FID and organic-fueled flame.

All HTM Site Files

det180

some DET PDFs . . . acrobat-but

  • DET 57 Aug 08 PDF 600k 8p
  • DET 56 08 PDF 560k 8p

DET-SRI-GC-200

DET-SRI GC 10p DJVu djvu

2006 Aust Prices

Product Summary
djvu
10p 204k djvu-s19
PDF acrobat-but

  • 1Ceramic Coated Thermionic Ion Source Beads
  • 2 Thermionic and Flame Ionisation Detectors for GC
  • 3 Thermionic Transducers
  • 4 Detector Replacement Parts
  • 5 Reactor Thermionic Ionisation Analysis
  • 6 TFID Stand-Alone Modules
NEW 06
 
  • DET NPD for the HP/Agilent 5890/6890 FID Base DJVu
  • DET Retrofit NPD for VARIAN GCs DJVu
  • DET Ceramic Beads for NPD Sources DJVu
  • Conversion of Agilent to Oxygenates SElective Detection DJVu
NEW 2004
  • Conversion of Agilent 6890 NPD to Oxygenate Selective Detection Agilent 6890 TID
NPD Beads Mar 04
DET 
Reports
some DET Structures - H'ware
New / Unique
Tandem TID
Tandem TID w/ Dual Electrometers
RTIA RTIA Reaction Thermionic Ionization Analyzer
some GC TID Detector Applications
DET Chromatograms
DET42-01 djvu-s
  • 1 Wine Analysis - TID-1 Detection of Diacetyl, Acetic, formic, propionic and lactic acids; glycerol; vanillin
  • 2 Diesel Fuel Analysis - TID-1 and NPD Detection of Carbazoles, Oxygenates and PAHs
  • 3 NPD Pesticides, Drugs & TID-1 on Gasless SRI GC - Explosives, Ooxygenates
DET41-01 djvu-s
  • 1 Gasless GC - New DET Detectors on SRI GCs
  • 2 Improved NP Detection for Agilent 6890 and Varian 3800 GC
  • Upgrades for
    Agilent  for 5890 6890 GC
  • Varian 3800 3400
    SRI 8610
DET Features
  • Constant Current ( Variable V ) Power Supply for better NPD Performance extends operation to other TID Selective Modes
  • Upgrade -ve Ion Electrometer available
    Standard GC NPD Electrometer
    can be used
  • Extra gas flow system, N2, Air, Oxygen, methane for various modes
    Note : High Purity NOT required
  • Upgrade and Replacement TID "beads" - higher sensitivity and more robust design
    & much Lower Cost
  • Other Thermionic Devices
  • Thermionic / FID; RTIA,
  • Tandem TID
Note : TID-1
Uses AIR as GC carrier gas
for explosives and oxygenates