Selecting a Pre-Packed Column

1. Choose the particle size and pore size

HYDROCELL media are available in 5 µm, 10 µm, 20 µm, 30 µm and 50 µm particle size of macroporous media for routine ion exchange, hydrophobic interaction, reversed phase and nucleic acid analysis and purification.
Hydrocell media are also produced nonporous polymeric beads for high-speed analysis and process control

Particle  Size

Pore  Size    

Applications

5  µm

500Å,  1500Å

High resolution,  Reversed Phase media for protein, polypeptide and oligonucleotide  analysis, and small-scale   separation.

10  µm

500Å,  1500Å

Ion Exchange,  Hydrophobic interaction and Reversed Phase media for analytical to  small-scale preparative

10 µm 

nonporous

Same as 10 µm porous  particle except producing from nonporous beads for high speed  analysis and preparation.

20 µm 

500Å, 1500  Å

Same as 10 µm porous  particle except for high pressure semi-preparative to preparative  applications

30 µm 

500Å, 1500  Å

Same as 10 µm porous  particle except for medium and low pressure preparative and process  applications

50 µm 

500Å, 1500  Å

Same as 10 µm particles  except for medium and low pressure preparative and process  applications

2. Select the column geometry

HYDROCELL columns are available in several sizes. We recommend 4.6 mm ID column for routine lab scale use.
For semi-preparative and preparative work choose a larger diameter 7.8 mm, 10 mm or 21.2 mm column.
For small scale work or more sensitive detection, choose a narrow-bore 1.0 or 2.1 mm ID column.
All standard Hydrocell 1500, 3000 and NP10 series of columns are constructed of PEEK or Stainless steel materials with 2 µm Titanium frit

Scale  of Separation

  Column Dimension

Recommended  Flow

Diameter  (mm)

Length  (cm)

Volume  (mL)

Volumetric  (mL/min)

Line velocity  (cm/hr)

Micro  (µg)

2.1

15

0.52

0.20-1.20

350-2100

Lab (µg to  mg)

4.6      

15

2.50

1.00-6.00

360-2200

7.8           

15

7.16

2.50-15.0

310-1860

Semi-Preparative  (mg)

10

15

11.50

4.00-24.0

310-1860

Preparative (mg to  grams)

21.2

15

50.60

15.0 -90

255-1530

3. Match the Column to the System

Each pre-packed HYDROCELL 1500, 3000 or NP10 series of columns are produced from 10 µm and 20 µm particle size with average pore size of 500Å, 1500 Å or nonporous PS-DVB polymeric beads for high pressure systems.
HYDROCELL 30 and 50 series of columns are designed for medium and low pressure preparative systems.
Choose the column that is suitable for your system environment. This will ensure that the back pressure generated on the column will not exceed the pressure limit of your system while operating under higher flow rates.

Fig. 1 - Pressure/Flow Relationship of NP10 series, 150x4.6mm columns

BioChrom-1

Fig. 2 - Pressure/Flow Relationship of 1500 series, 150x4.6mm columns
BioChrom-2

Fig. 3 - Pressure/Flow Relationship of Reversed Phase RP 10G, 150X4.6 mm columnBioChrom-3

4. Choose the HYDROCELL Chemistry

Product

Functional  Group

Particle Size (µm)

Pore  Size  (A)                           

Dynamic
Loading Capacity
(column volume/mL)

Ion Exchange Chromatography 

DEAE 1500

Diethylaminoethyl    

10

500

50 mg

DEAE 3000

Diethylaminoethyl    

10

1500

45 mg

DEAENP10   

Diethylaminoethyl

10

Non-porous

35mg

QA 1500

Diethylmethylaminoethyl

10

500

50 mg

QA 3000

Diethylmethylaminoethyl

10

1500

45 mg

QA NP10

Diethylmethylaminoethyl

10

non-porous

35 mg

CM 1500

Carboxymethyl

10

500

45 mg

CM 3000

Carboxymethyl

10

1500

40 mg

CM NP10

Carboxymethyl

10

non-porous

25 mg

SP 1500

Sulfopropyl      

10

500

45 mg

SP 3000

Sulfopropyl      

10

1500

40 mg

SP NP10

Sulfopropyl      

10

non-porous

25 mg

NS 1500

Quaternized  Amine

10

500

60 mg

Hydrophobic Interaction  Chromatography 

C3 1500

Allyl                 

10

500

30 mg

C3 3000

Allyl

10

1500

25 mg

C3 NP10

Allyl

10

non-porous

15 mg

C4 1500

Butyl

10

500

30 mg

C4 3000

Butyl

10

1500

25 mg

C4  NP10       

Butyl

10

non-porous

15 mg

Phenyl  1500

Phenyl

10

500

35 mg

Phenyl 3000 

Phenyl

10

1500

30 mg

Phenyl NP10 

Phenyl

10

non-porous

20 mg

Reversed-Phase Chromatography 

RP 5T

Base  PS-DVB   

5

140

60 mg

RP 5G

PS-DVB with  coating

5

500

45 mg

RP 10G

PS-DVB with  coating

10

500

40 mg

RP 5S

Base  PS-DVB   

5

500

50 mg

RP 10S

Base  PS-DVB            

10

500

45 mg

RP 5D

Base  PS-DVB   

5

1500

45 mg

RP 10D

Base  PS-DVB   

10

1500

40 mg

BioChrom-logo04

HYDROCELL Column Selection Guide 
see Selection Chart pic

08

NEW Website

Chromalytic Technology - Australian Distributors 'specialising in chromatography'
:  GC, HPLC & Fluid Transfer Products; Instrumentation  Home : Sections

07

the Web Ask chromtech.com.au