The New Standard in Semivolatile GC/MS Columns Rtx5SIL-MS- Superior Inertness provides more accurate quantitation at lower concentrations
- Optimised dimensions produce more linear calibration curves
- Improved resolution of semi-volatile compounds
Guaranteed lower Bleed than other phenyl/methyl phases Rtx-5SIL MS #59204 6p in DJVU format40k/page - Inertness/Dimensions . . 2
- Excellent GC/MS Seperations
- Silarylene polymer structure for low GC/MS bleed . . 4
- Challenges in Semivolatile Analysis
- Benefits of Rtx-5SIL MS . .. 5
- Cat.#s & Accessories . . 6
|
Rtx5-Sil MS | ID(mm) | df(um) | Temp Limits | 30-m | Integra Guard Suffix | | | | | | 5-m | 10-m | | 0.25 | 0.25 0.50 1.00 | -60 to 330/350C -60 to 330/350C -60 to 330/350C | 12723 12728 12753 | -124 -124 -124 | -127 -127 -127 | | 0.28 | 0.25 0.50 1.00 | -60 to 330/350C -60 to 330/350C -60 to 330/350C | 12793 12794 12795 | -243 -243 -243 | -244 -244 -244 | | 0.32 | 0.50 1.00 | -60 to 330/350C -60 to 325/350C | 12739 12754 | -125 -125 | -128 -128 |
|
|
| Revolutionary New Column Designed for GC Volatiles Analysis Rtx-VGC- Better resolution than VRX phases for volatiles analysis using PID/ELCD
- Provides fastest analysis time of VOCs without co-elutions.
- Inceases lab productivity and sample throughput.
- Resolves gases and early eluting compounds
Rtx-VGC #59217 6p DJVU format 40k/page - Increased Prdouctivity - Fastest
- Analysis Time for Targeted VOCs . . 2
- Tuned Selectivity
Improved Quantitative Reliability Unequaled Resolution . . 3
- GCs of EPA 502.2, 601`, 602, 8010 or 8021 . . 4
- What are the challenges of volatile organic (VOC) analyses . . .
Benefits of Rtx-VGC columns . . . 5
- Cat.#s accessories . . . 6
|
Rtx-VMS |
ID(mm) | df(um) | Temp Limits | 30-m | 60-m | 75-m | 100-m | | 0.25 |
1.40 | -40 to 240/260C | 19415 | 19416 |
| | 0.32 | 1.80 | -40 to 240/250C | 19419 | 19420 | | | 0.45 | 2.55 | -40 to 240/250C | 19408 | | 19409 |
| 0.53 | 3.00 | -40 to 240/250C | 19485 | 19488 | 19474 | 19489 |
| |
| 20-m | 40-m | | | 0.18 | 1.00 | -40 to 240/260C | | | | |
|
|

| Rtx-CLPesticides #59699 Rtx-CLPesticides - 30m 0.32mm 0.50um & Rtx-CLPesticides 11 - 30m 0.32mm 0.25um- thse offer a superior replacemnt to previos 1701; thse always had low responses for ddT and Methoxychlor and quickly exhibits unacceptable breakdown of ddT and Endrin
- base-line separation of 22 chlorinated pesticides in US EPA 8081 in less thn 22 minutes
- the Rtx-CLPesticides 11 column is the ideal confirmation column. It offers 4 elution order changes, base-line resolution in 24 minutes
|